Tender For corrigendum : supply of lab furniture - wall bench wb 1 , over head storage cabinet with frame structure , wall bench wb 2 , wall bench wb 3 , low constant volume lcv type bench fume hood , exhaust fan 400 mm dia , spot extractor , exhaust fan 315 mm dia , wall bench wb 4 , wall bench wb 5 , wall bench wb 6 , wall bench wb 7 , island bench ib 1 , island bench ib 2 , wall bench wb 1 and 4 , wall bench wb 2 size as per specs document , corner bench cb 1 , wall bench wb 3 detail as per specs document , island bench ib 1 detail as per specs document , island bench ib 2, 3 ,4 , wall bench wb 5 detail as per specs document , wall bench wb 6 detail as per specs document , wall bench wb 7 detail as per specs document , wall bench wb 7 and 8 , corner bench cb 3 , glassware storage cabinet gsc , bench wb 6 detail as per specs document , corner bench cb 2 detail as per specs document , wall mounted storage cabinet , lab stool , anti vibration table avt , wall bench wb 1 detail as per specs document , exhaust fan 315 mm dia detail as per specs document , wall bench wb 2 size detail as per specs document , lab stool detail as per specs document , wall bench wb 3 and 4 detail as per specs document , corner bench cb 1 detail as per specs document , wall mounted storage cabinet detail as per specs document , exhaust ducting in pp plus frp round shape construction , fume hood superstructure , fume hood worktop , service valves , electrical services , controls as per specification document , fume hood understructure , fume hood under cabinet chemical storage purpose , accessories as per item 53 in specification document , fume hood superstructure as per specification document , fume hood worktop as per specification document , service valves as per specification document , electrical services as per specification document , fume hood understructure as per specification document , fume hood undercabinet chemical storage purpose , accessories as per specification document
Tender For science lab and geography lab items - lab items, ammeter dc to ac, analog multimeter, andersonand schering andhay and kelvin and maxwell and de sauty and wiens bridges, apparatus for measurement of capacitance and inductance using impedance at different frequency, apparatus for studying diffraction from reflection grating model, apparatus to determine the rydbergs constant with the help of diffraction grating and hydrogen discharge tube. complete with high voltage power supply, grating and spectrometer., apparatus to determine the temp coeff. of resistance of platinum complete with all accessories., apparatus to determine the viscosity of fluid using poiseuileas method, apparatus to draw b-h curve of ferromagnetic material with the help of cro, apparatus to study tunnel diode, apparatus to study charging and discharging of a capacitor., apparatus to study response curve for lcr circuits and to determine the resonance frequency., apparatus to study specific resistance and energy gap of a semiconductor., apparatus to study the absorption spectra of iodine vapour complete with white light source. power supply. grating, and spectrometer., apparatus to study transistorised regulated power supply., apparatus to verify newtons law of cooling, audio frequency generator, babinet compensator with optical bench and accessories, ballistic galvanometer with lamp and scale arrangement, bending of beam apparatus to determine youngs modulus, biprism assembly, biquartz or half shade polari meter, value of mechanical apparatus to determine the calendar and barnets equivalent of heat, c.r.o. dual trace 20 mhz, c.r.o. dual trace 40 mhz, cantilever to determine youngs modulus, choke of mercury lamp, complete apparatus for study of zeeman effect with all accessories for determination of lande-g- factor, complete apparatus to determine resolving power of telescope, complete apparatus to determine the heating efficiency of electrical kettle with various voltages, complete apparatus to verify law of parallel and perpendicular axes for moment of inertia, complete apparatuse to determine e/m by milikans method, complete setup to find the wavelength of sodium light with the help of fresnels biprism., compound pendulum/bar pendulum, compton effect experiment, cro single trace 20 mhz, characteristic apparatus dielectric constant, digital multi meter, drill machine with all size bits, e/m by helical method, digital storage oscilloscope 40 mhz, f.e.t. amplifier, four probe method, frank hertz experiment, fresnel biprism diffraction apparatus model, function generator 0.3 to 3 mh, function generator hz to 10 mhz, half wave and full wave rectifier apparatus with built in power supply, hall probe method for measurement of resistivity. complete with hall effect setup, hall probes, digital gauss meter, electromagnet and constant current supply., hartley and colpitts oscillator, horizontal torsion apparatus, hybrid solar and wind energy trainer., hydrogen spectra balmer series apparatus, impedance and power factor of lcr circuit, induction hot plate with induction pots, jaegers apparatus to determine the surface tension, laser raman spectrometer(ccd based), lees disc, m.o.s.f.e.t characteristic apparatus, magnetostriction with michelson interferometer model c" ho-ed-int- 06m, measurement of low resistance by carey foster s bridge complete with power supply., measurement of thickness of thin wire with laser complete setup, measurement of wave length of he-ne laser using ruler with laser complete setup, mercury lamp, newtons rings apparatus complete with travelling microscope, power supply and sodium lamp., photo diode characteristic apparatus, photo transistor characteristic apparatus, photoconductivity experiments, physical balance, plancks constant using solar cell, plug key one way/two way, scarles apparatus to determine the coefficient of thermal conductivity, series and parallel resonance circuit, single slit diffraction and heisenbergs uncertainity, slotted w
Tender For supply and installation of various veterinary lab equpments - electro fusion machine with accessories and spares, electro fusion machine with accessories and spares (as per specifications mentioned in tender document), ultrasound machine with accessories, ultrasound machine with accessories (as per specifications mentioned in tender document), bench top controlled gas embryo culture incubator with accessories, bench top controlled gas embryo culture incubator with accessories (as per specifications mentioned in tender document), cryocan ba-20 and ba-03 with canister, cryocan ba-20 with canister (as per specifications mentioned in tender document), cryocan ba-03 with canister (as per specifications mentioned in tender document), water purification system, water purification system (as per specifications mentioned in tender document)
Tender For corrigendum : civil lab equipments - digital compression testing machine capacity, hydraulic bench, digital direct shear test apparatus, 2kn, total station with stand and all accessories, gnss based survey, dgps (digital global positioning system), cube mould 150 mm, cube mould 70.6mm, digital electronic balance 10 kg capacity, electronic balance capacity 30 kg, vicat apparatus:, flash and fire point apparatus, reynold s apparatus, vernier transit theodolite, universal oven, permeability apparatus (is: 2720 part 17), mortar cube vibrating machine, b. o. d. incubator, curing tank, torsion testing machine, rockwell hardness testing machine, metallurgical microscope, compression testing machine, aggregate impact testing machine, digital planimeter, ductility test apparatus
Tender For corrigendum : providing of calibration services - relay test bench test sets available at lcc rtm; relay test bench test sets available at lcc rtm; nabl labs; lab
Tender For bid to ras setting of drone lab and upgrdation of ai lab-(a) set up of a drone lab and up-gradation of ai lab at air hangar. (b) hardware indicated at subsequent paragraphs as per the specifications and quantity need to be provided. (c) requisite software towards operationalizing the lab along with hardware to be provided by the vendor. (d) following item needs to be provided by vendor: (i) qty one fully operational drone as per the indicated specifications (including tools, testers, spares and requisite accessories) for hands on experience (minimum specification annexed). (ii) qty two training/demonstration models with provision of assembly & disassembly of various sub-systems / sub-assemblies for better technical appreciation (minimum specification annexed). (e) qty two computer-based simulators with remote controller for hands on experience on flying of drones. (f) test jigs related to various major components of the drone should be provided. the test jigs should include (not limited to) thrust bench for motor performance testing. (g) ai based video analytics hardware/ software as per the minimum specifications annexed. (h) the vendor need to undertake networking of entire lab set up with capability of extending to at least 16 terminals including necessary hardwires. (i) installation and operationalization of the lab along with all the hardware supplied by the vendor at customer premises. installation should include provision and setting up of pvc foam boards indicating instructions, information, safety board and other training requirements. the vendor need to provide 3d model design of the lab layout along with technical proposal considering the space availability and aesthetics of the lab.-quantity - 1- msme exemption - yes | startup exemption - yes
Tender For e-tendering on partial turnkey basis for procurement of set of battery (32 nos. of smf ups battery 12v, 42ah) for ups of three phase 20 position fully automatic energy test bench class 0.2 bearing sr. no. 1422-2016 make meter test poland in meter testing lab at m&t solan. . [t.s. no.: 07/2024-25; name of scheme: minor capital works(indivisible); estimate sanctioned date: 01.01.2025]